Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: Answers

Area: Tools


Last Modified: September 18, 2019
Version Found: v19.1
Version Fixed: v19.2
Bug ID: 1607134084

Why does the Intel® Quartus® Prime Pro edition software version 19.1 show PR(Partial Reconfiguration) programming failures using Intel Stratix®10 devices?

Description

Due to a problem with Intel® Quartus® Prime Pro edition software version 19.1, you may see PR programming failures after 100 to 500 successful PR operations using Intel® Stratix®10 devices.

Workaround/Fix

This problem is fixed beginning with the Intel® Quartus® Prime Pro edition software version 19.2.