Article ID: 000081213 Content Type: Troubleshooting Last Reviewed: 10/21/2013

Why is the path to the ModelSim Altera Edition software set up incorrectly ?

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® II software version 13.0, after installation, the default path to the ModelSim-Altera software is incorrectly set to:

    <install_directory>\win32aloem (for example, C:\altera\13.0.0.156\win32aloem)

    Resolution

    To correct this issue, open the Options dialog box by selecting Options on the Tools menu. Select the EDA Tool Options category, and change the path to the following:

    <install_directory>\modelsim_ase\win32aloem (for example, C:\altera\13.0.0.156\modelsim_ase\win32aloem)

    This problem is fixed beginning with the Quartus II software version 13.0 SP1.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices