Intel® Server Board D40AMP Family BIOS and System Firmware Update Package (SFUP) for Windows* and Linux*

723055
2/23/2022

Introduction

This download record contains the BIOS and firmware update package for the Intel® Server Board D40AMP Family for Windows* and Linux* (R01.02.0006)

Available Downloads

  • OS Independent
  • Size: 72.4 MB
  • SHA1: 8E738C02562B67033CCC674102B7B1ED8704172F

Detailed Description

Overview

This download record contains the BIOS and System Firmware Update Package (SFUP) for the Intel® Server Board D50TNP Family and appropriate Intel® Server System D40AMP Family —for use with Windows* and Linux*

 

Purpose

Windows and Linux System Firmware Update Package (SFUP) Installation and Operation Instructions

Intel highly recommends reading the ReleaseNotes_SFUP_AMP_1.0.3.txt in its entirety before performing the system update. Verifying that your system meets the documented requirements will ensure a successful update and provide the most reliable system functionality after the update has completed.

 

Released - January 7, 2022

This update package includes the following production level system software updates and update utilities:

   System BIOS    - SE5C620.86B.01.02.0006

   ME Firmware    - 04.04.04.56

   BMC Firmware   - 2.87.3ccd0377.

   FRUSDR         - 0.20

   DCPMM          - 2.2.0.1553

   CPLD           - v1P7

   sysfwupdt.efi  - Version 14.2 Build 11

 

Supported products

Intel® Server Board D40AMP Family

Contact Intel for pre-production hardware support requirements

 

Important Notes

Firmware check is not applicable, hence updates will be triggered even when the versions in the system and in the SFUP package are same.

Do NOT interrupt or reboot or remove power from your system during the update process. Doing so may render your system inoperable.

Do NOT attempt to down rev the system software once loaded on to the system. Doing so may render your system inoperable.

All updates provided in this package are installed using the Windows and Linux operating environment only.

Do not modify any of the script files. The scripts as written will provide the most reliable update experience.

 

System software requirements

To update the system software stack to the versions included in this update package, the system software stack currently installed on the target server system MUST meet the following, or else the update may fail:

  •  System BIOS     - Production version SE5C620.86B.01.02.0001 or later
  •  BMC Firmware  - Production version 2.86.754fda22  or later
  •  FRUSDR            - Production version 0.18 or later 

 

Pre-requisites before running Windows and Linux scripts - refer to ReleaseNotes_SFUP_AMP_1.0.3.txt

 