General-Purpose I/O User Guide: Agilex™ 5 FPGAs and SoCs
ID
813934
Date
8/04/2025
Public
1. Agilex™ 5 General-Purpose I/O Overview
2. Agilex™ 5 HSIO Banks
3. Agilex™ 5 HVIO Banks
4. Agilex™ 5 HPS I/O Banks
5. Agilex™ 5 SDM I/O Banks
6. Agilex™ 5 I/O Troubleshooting Guidelines
7. GPIO FPGA IP
8. Programmable I/O Features Description
9. Document Revision History for the General-Purpose I/O User Guide: Agilex™ 5 FPGAs and SoCs
2.5.1. I/O Standard Placement Restrictions for True Differential I/Os
2.5.2. Placement Restrictions for True Differential and Single-Ended I/O Standards in the Same or Adjacent HSIO Bank
2.5.3. VREF Sources and Input Standards Grouping
2.5.4. HSIO Pin Restrictions for External Memory Interfaces
2.5.5. RZQ Pin Requirement
2.5.6. I/O Standards Implementation Based on VCCIO_PIO Voltages
2.5.7. I/O Standard Selection and I/O Bank Supply Compatibility Check
2.5.8. Simultaneous Switching Noise
2.5.9. HPS Shared I/O Requirements
2.5.10. Clocking Requirements
2.5.11. Clock Restrictions for GPIO Interfaces
2.5.12. SDM Shared I/O Requirements
2.5.13. Unused Pins
2.5.14. VCCIO_PIO Supply for Unused HSIO Banks
2.5.15. HSIO Pins During Power Sequencing
2.5.16. Drive Strength Requirement for HSIO Input Pins
2.5.17. Maximum DC Current Restrictions
2.5.18. 1.05 V, 1.1 V, or 1.2 V I/O Interface Voltage Level Compatibility
2.5.19. Connection to True Differential Signaling Input Buffers During Device Reconfiguration
2.5.20. LVSTL700 I/O Standards Differential Pin Pair Requirements
2.5.21. Implementing a Pseudo Open Drain
2.5.22. Allowed Duration for Using RT OCT
2.5.23. Single-Ended Strobe Signal Differential Pin Pair Restriction
2.5.24. Implementing SLVS-400 or DPHY I/O Standard with 1.1 V VCCIO_PIO
2.5.11. Clock Restrictions for GPIO Interfaces
Adhere to these clock sharing guidelines when designing with multiple TX or multiple RX registers in the same I/O lane.
- When placing multiple TX or multiple RX SDR registers in the same I/O lane, you must use the same reference clock to drive these TX or RX registers. This rule applies when the register packing option is enabled in your FPGA design.
- When placing multiple TX or multiple RX DDIO registers in the same I/O lane, you must use the same reference clock to drive these registers.