1. Agilex™ 5 Clocking and PLL Overview
2. Agilex™ 5 Clocking and PLL Architecture and Features
3. Agilex™ 5 Clocking and PLL Design Considerations
4. Clock Control Altera™ FPGA IP Core
5. IOPLL FPGA IP
6. I/O PLL Reconfiguration
7. Document Revision History for the Clocking and PLL User Guide: Agilex™ 5 FPGAs and SoCs
2.2.1. PLL Features
2.2.2. PLL Usage
2.2.3. PLL Locations
2.2.4. PLL Architecture
2.2.5. PLL Control Signals
2.2.6. PLL Feedback Modes
2.2.7. Clock Multiplication and Division
2.2.8. Programmable Phase Shift
2.2.9. Programmable Duty Cycle
2.2.10. PLL Cascading
2.2.11. PLL Input Clock Switchover
2.2.12. PLL Reconfiguration and Dynamic Phase Shift
2.2.13. PLL Calibration
6.1.1. Release Information for EMIF Calibration IP
6.1.2. Setting Up the IOPLL FPGA IP
6.1.3. Setting Up the EMIF Calibration IP
6.1.4. Connectivity Between IOPLL FPGA IP and EMIF Calibration IP
6.1.5. Axilite Interface Ports in the EMIF Calibration IP
6.1.6. Reconfiguration Guideline for HSIO I/O PLLs
6.1.7. Design Example for HSIO I/O PLL Reconfiguration
6.2.2.1. Read and Write Operations via Avalon® Memory-Mapped Interface
6.2.2.2. Enabling Reconfiguration for The Desired I/O PLL
6.2.2.3. Clearing off Calibration Statuses
6.2.2.4. Reconfiguring The I/O PLL
6.2.2.5. Enabling Recalibration for HVIO PLLs
6.2.2.6. Requesting Recalibration of I/O PLL
6.2.2.7. Clock Gating (Optional)
5.2.3. IOPLL IP Parameters - Cascading Tab
Parameter | Value | Description |
---|---|---|
Connect to an upstream PLL through Core clock Network Cascading (create a permit_cal input signal) | On or Off | Turn on to create an input port to enable destination (downstream) PLL power-up calibration. Connect source (upstream) PLL locked signal to this input port. |
Connect outclk to a downstream PLL through Core Clock Network Cascading | On or Off | Turn on to configure the PLL as an upstream PLL. Connect (upstream) PLL output clock signal to the refclk port of (downstream) PLL. |
cascade_out source | 5–6 18 | Specifies which output clock to be used as cascading source. |
Create an adjpllin or cclk signal to connect with an upstream PLL | On or Off | Turn on to create an input port, which indicates that this PLL is a destination and connects with a source (upstream) PLL. |
Create a cascade_out signal to connect to a downstream PLL. | On or Off | Turn on to create the cascade_out port, which indicates that this PLL is a source and connects with a destination (downstream) PLL. |
Enable dynamic reconfiguration of PLL | On or Off | Select this option to enable the dynamic reconfiguration of this IOPLL IP. Creates AVL interface reconfiguration port, through which current M, N, and C counter settings are read from the IOPLL IP, and new settings are written to the IOPLL IP. |
Enable dynamic reconfiguration of PLL using Calibration IP | On or Off | Select this option to enable the dynamic reconfiguration of this IOPLL IP (in conjunction with EMIF Calibration IP). This option initiates calbus reconfiguration ports, which allow for the reading of the current M, N, and C counter settings from the IOPLL IP and the writing of new settings to the IOPLL IP. |
18 When outclk6 is enabled, cascade_out source can only be C6; cascade_out source can be C5 only if outclk6 is not enabled.