SEU Mitigation User Guide: Agilex™ 5 FPGAs and SoCs

ID 813649
Date 2/17/2025
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

6. Document Revision History for the SEU Mitigation User Guide: Agilex™ 5 FPGAs and SoCs

Document Version Quartus® Prime Version Changes
2025.2.17 24.3 Updated Figure: READ_SEU_STATS (0x40) Mailbox Command in the Configuration Debugger Tool.
2024.11.25 24.3
  • Updated Table: Advanced SEU Detection Intel® FPGA IP Current Release Information.
  • Updated Figure: Configuration Debugger Response to read_seu_error Mailbox Command (0x3C).
  • Updated the note about using Fault Injection Debugger in Quartus® Prime software in Fault Injection Debugger.
  • Added QSF setting information for the Error Detection CRC setting options in Setting Up the SEU Mitigation Features.
  • Added new Figure: Selecting Sector-based .rbf in Fault Injection Debugger Tool to Performing External Scrubbing.
  • Added steps about programming fuse file in Blowing Fuse Bit to Enable Injecting All Error Types.
  • Updated the description for cable, index, and time in Table: Fault Injection Debugger Command-Line Interface Arguments for Agilex™ 5 Devices.
2024.09.20 24.1
  • Removed information about triple modular redundancy area from Table: SEU Mitigation Areas and Approaches for Agilex™ 5 Devices.
  • Updated the M20K features in Table: ECC for M20K Blocks.
  • Updated Secure Device Manager ECC and SmartVID.
  • Updated Figure: Configuration Debugger Response to read_seu_error Mailbox Command (0x3C).
  • Updated Retrieving SEU Statistics using Mailbox Command.
  • Updated Injecting Errors to Predefined Safe Locations: GUI with Tcl Console.
  • Updated Injecting Error to Predefined Safe Locations: Mailbox Command.
  • Added new figures:
    • Figure: Setting the SEU_ERROR Pin
    • Figure: Fault Injection Debugger Window
    • Figure: Software Object File Configuration Using Fault Injection Debugger Tool
    • Figure: Example of Listed Predefined Safe Locations at Sector 3, 4, 5, 10, 11, 12, 19, 20, and 21
    • Figure: Single-Bit Error Injection at Sector 3 Using Command Line quartus_fid
    • Figure: Single-Bit Error Injection at Sector 3 Using Tcl Console
  • Updated Secure Device Manager ECC and SmartVID Errors Detection.
  • Updated the following tables:
    • Table: SDM and Subsystem ECC Error Message Bits Description
    • Table: SmartVID Error Message Bits Description
  • Made editorial edits throughout the document.
2024.04.01 24.1 Initial release.