2.3.1. Performing Remote System Update Debugging
To perform remote system update debugging:
- Click Hardware Setup to select a hardware setup to use for debugging.
- Click Load Device and select a device from the drop-down list if more than one device exists in the hardware setup.
- Click Flash.
Note: The Flash tab is disabled if the selected device is not SDM-based.
- Click Auto-detect to auto-detect the QSPI Flash that is attached to the device.
- Click Remote System Update.
- Click Reset when you wish to reset the page.
- Click Image Update to trigger reconfiguration of an image at the specified start address.
- Click Read Image Address (Configuration Pointer Block) to list all the application image addresses from the Configuration Pointer Block (CPB0 or CPB1).
- Click Read Image Address (Sub-partition Table) to list all the RSU partitions information from the Sub-partition Table (SPT0 or SPT1).
- Click Read RSU Status to read the current RSU status information that includes:
- Current images address displays the current image address.
- Failing image address displays the failing image address when an error occurs.
- Error code and corresponding Error Type upon the RSU failure.
- Version displays the current software version.
- Error Source displays the source information of the error.
- Error Location displays the error location of the failing image.
- Error Details displays the error details of the failing image.
- Current Image Retry displays the current image retry counter value.
- Click Clear (Current Image Retry Counter) to clear the Current Image Retry Counter value.
- Click Clear (Error Log) to remove the Error Log data.
Figure 5. Remote System Update