R-Tile Avalon® Streaming Intel® FPGA IP for PCI Express* User Guide
ID
683501
Date
12/06/2024
Public
A newer version of this document is available. Customers should click here to go to the newest version.
1. About the R-Tile Avalon® Streaming Intel® FPGA IP for PCI Express
2. IP Architecture and Functional Description
3. Advanced Features
4. Interfaces
5. Parameters
6. Troubleshooting/Debugging
7. R-Tile Avalon® Streaming Intel® FPGA IP for PCI Express* User Guide Archives
8. Document Revision History for the R-Tile Avalon® Streaming Intel® FPGA IP for PCI Express* User Guide
A. Configuration Space Registers
B. Root Port Enumeration
C. Implementation of Address Translation Services (ATS) in Endpoint Mode
D. Packets Forwarded to the User Application in TL Bypass Mode
E. Margin Masks for the R-Tile Avalon Streaming Intel FPGA IP for PCI Express
3.2.2.5.1. VirtIO Common Configuration Capability Register (Address: 0x012)
3.2.2.5.2. VirtIO Common Configuration BAR Indicator Register (Address: 0x013)
3.2.2.5.3. VirtIO Common Configuration BAR Offset Register (Address: 0x014)
3.2.2.5.4. VirtIO Common Configuration Structure Length Register (Address 0x015)
3.2.2.5.5. VirtIO Notifications Capability Register (Address: 0x016)
3.2.2.5.6. VirtIO Notifications BAR Indicator Register (Address: 0x017)
3.2.2.5.7. VirtIO Notifications BAR Offset Register (Address: 0x018)
3.2.2.5.8. VirtIO Notifications Structure Length Register (Address: 0x019)
3.2.2.5.9. VirtIO Notifications Notify Off Multiplier Register (Address: 0x01A)
3.2.2.5.10. VirtIO ISR Status Capability Register (Address: 0x02F)
3.2.2.5.11. VirtIO ISR Status BAR Indicator Register (Address: 0x030)
3.2.2.5.12. VirtIO ISR Status BAR Offset Register (Address: 0x031)
3.2.2.5.13. VirtIO ISR Status Structure Length Register (Address: 0x032)
3.2.2.5.14. VirtIO Device Specific Capability Register (Address: 0x033)
3.2.2.5.15. VirtIO Device Specific BAR Indicator Register (Address: 0x034)
3.2.2.5.16. VirtIO Device Specific BAR Offset Register (Address 0x035)
3.2.2.5.17. VirtIO Device Specific Structure Length Register (Address: 0x036)
3.2.2.5.18. VirtIO PCI Configuration Access Capability Register (Address: 0x037)
3.2.2.5.19. VirtIO PCI Configuration Access BAR Indicator Register (Address: 0x038)
3.2.2.5.20. VirtIO PCI Configuration Access BAR Offset Register (Address: 0x039)
3.2.2.5.21. VirtIO PCI Configuration Access Structure Length Register (Address: 0x03A)
3.2.2.5.22. VirtIO PCI Configuration Access Data Register (Address: 0x03B)
4.3.1. Avalon® Streaming Interface
4.3.2. Precision Time Measurement (PTM) Interface (Endpoint Only)
4.3.3. Hot Plug Interface
4.3.4. Interrupt Interface
4.3.5. Hard IP Reconfiguration Interface
4.3.6. Error Interface
4.3.7. Completion Timeout Interface
4.3.8. Configuration Intercept Interface
4.3.9. Power Management Interface
4.3.10. Hard IP Status Interface
4.3.11. Page Request Services (PRS) Interface (Endpoint Only)
4.3.12. Function-Level Reset (FLR) Interface (Endpoint Only)
4.3.13. SR-IOV VF Error Flag Interface (Endpoint Only)
4.3.14. General Purpose VSEC Interface
5.2.3.1. Device Capabilities
5.2.3.2. VirtIO Parameters
5.2.3.3. Link Capabilities
5.2.3.4. Legacy Interrupt Pin Register
5.2.3.5. MSI Capabilities
5.2.3.6. MSI-X Capabilities
5.2.3.7. Slot Capabilities
5.2.3.8. Latency Tolerance Reporting (LTR)
5.2.3.9. Process Address Space ID (PASID)
5.2.3.10. Device Serial Number Capability
5.2.3.11. Page Request Service (PRS)
5.2.3.12. Access Control Service (ACS)
5.2.3.13. Power Management
5.2.3.14. Vendor Specific Extended Capability (VSEC) Registers
5.2.3.15. TLP Processing Hints (TPH)
5.2.3.16. Address Translation Services (ATS) Capabilities
5.2.3.17. Precision Time Measurement (PTM)
4.4.1.2. Receive Signals
Signal Names | Direction | Descriptions/Notes | Clock Domain |
---|---|---|---|
lnX_pipe_direct_rxdatavalid1_o | Output | This signal qualifies rxdata[63:32]. | lnX_pipe_direct_pld_rx_clk_out_o |
lnX_pipe_direct_rxdatavalid0_o | Output | This signal qualifies rxdata[31:0]. | lnX_pipe_direct_pld_rx_clk_out_o |
lnX_pipe_direct_pipe_rxdata_o[63:0] | Output | Receive data bus | lnX_pipe_direct_pld_rx_clk_out_o |
lnX_pipe_direct_rxelecIdle_o | Output | This signal indicates the receiver detection of an Electrical Idle. It is an asynchronous signal.
Note: This signal may toggle during continuous traffic. Per the PIPE Spec 5.1.1 section 9.4, the Soft IP controller must not rely on this signal for Electrical Idle detection when operating at gen2 or higher speeds. This toggling may not be observed in simulation and is a known limitation of the R-Tile simulation model.
|
Async |
The following timing diagrams provide an illustration of the behaviors of the PIPE Direct RX Datapath signals:
Figure 44. PIPE Direct RX Datapath
Note: At Gen1 and Gen2 speeds, only the 10 LSB bits in the upper and lower segments of the LnX_pipe_direct_pipe_rxdata_o bus contain valid data. Bits [31:10] and [63:42] are don't-cares.