1. Overview
2. Getting Started
3. F-Tile Ethernet Hard IP Parameters
4. Functional Description
5. Clocks
6. Resets
7. Interface Overview
8. Configuration Registers
9. Supported Modules and IPs
10. Supported Tools
11. F-Tile Ethernet Intel® FPGA Hard IP User Guide Archives
12. Document Revision History for the F-Tile Ethernet Hard IP User Guide
4.4.1. Features
4.4.2. PTP Timestamp Accuracy
4.4.3. PTP Client Flow
4.4.4. RX Virtual Lane Offset Calculation for No FEC Variants
4.4.5. Virtual Lane Order and Offset Values
4.4.6. UI Adjustment
4.4.7. Reference Time Interval
4.4.8. Minimum and Maximum Reference Time (TAM) Interval for UI Measurement (Hardware)
4.4.9. UI Value and PMA Delay
4.4.10. Routing Delay Adjustment for Advanced Timestamp Accuracy Mode
4.4.11. Routing Delay Adjustment for Basic Timestamp Accuracy Mode
5.1. Clock Connections in Single Instance Operation
5.2. Clock Connections in Multiple Instance Operation
5.3. Clock Connections in MAC Asynchronous FIFO Operation
5.4. Clock Connections in PTP-Based Synchronous and Asynchronous Operation
5.5. Clock Connections in Synchronous Ethernet Operation
5.6. Custom Cadence
7.1. Status Interface
7.2. TX MAC Avalon ST Client Interface
7.3. RX MAC Avalon ST Aligned Client Interface
7.4. TX MAC Segmented Client Interface
7.5. RX MAC Segmented Client Interface
7.6. MAC Flow Control Interface
7.7. PCS Mode TX Interface
7.8. PCS Mode RX Interface
7.9. FlexE and OTN Mode TX Interface
7.10. FlexE and OTN Mode RX Interface
7.11. Custom Rate Interface
7.12. 32-bit Soft CWBIN Counters
7.13. Reconfiguration Interfaces
7.14. Precision Time Protocol Interface
7.15. Auto-Negotiation and Link Training Interface
7.2.1. TX MAC Avalon ST Client Interface with Disabled Preamble Passthrough
7.2.2. TX MAC Avalon ST Client Interface with Enabled Preamble Passthrough
7.2.3. Using MAC Avalon ST skip_crc Signal to Control Source Address, PAD, and CRC Insertion
7.2.4. Using MAC Avalon ST i_tx_error Signal to Mark Packets Invalid
7.4.1. TX MAC Segmented Client Interface with Disabled Preamble Passthrough
7.4.2. TX MAC Segmented Client Interface with Enabled Preamble Passthrough
7.4.3. Using MAC Segmented skip_crc Signal to Control Source Address, PAD, and CRC Insertion
7.4.4. Using MAC Segmented i_tx_mac_error to Mark Packets Invalid
7.11. Custom Rate Interface
The F-Tile Ethernet Hard IP Custom Rate Interface is available when you enable Use external custom cadence controller option. The interface accounts for differences between the system clock and the TX transceiver PLL rate.
Signal Name |
Width | Description |
---|---|---|
i_custom_cadence | 1 | Custom data valid signal.
Connect this signal either to a counter that produces a steady data valid cadence that corresponds to the ratio between the clock rate used and the clock rate required, or a system that increases or decreases the data valid cadence based on the current occupancy of transceiver TX FIFO or an external TX FIFO.
Note: The TX reset sequence requires valid custom cadence pulses. You must start driving i_custom_cadence before o_tx_lanes_stable assert. You may drive i_custom_cadence as soon as o_tx_pll_locked asserts, and any external cadence generation logic and clocks are out of reset.
|
Figure 54. Custom rate Interface Behavior with a Fixed Data Valid Ratio
A counter producing a steady ratio of high and low pulses to balance the flow through a channel can drive the custom cadence rate interface.