INQUIRE: CONVERT Specifier
The CONVERT
specifier asks what type of data conversion is in effect for a file. It takes
the following form:
CONVERT =
fm
- fm
- Is a scalar default character variable that is assigned one of the following values:'LITTLE_ENDIAN'If the file is connected with little endian integer and IEEE* floating-point data conversion in effect'BIG_ENDIAN'If the file is connected with big endian integer and IEEE floating-point data conversion in effect'CRAY'If the file is connected with big endian integer and CRAY* floating-point data conversion in effect'FDX'If the file is connected with little endian integer and VAX* processor F_floating, D_floating, and IEEE binary128 data conversion in effect'FGX'If the file is connected with little endian integer and VAX processor F_floating, G_floating, and IEEE binary128 data conversion in effect'IBM'If the file is connected with big endian integer and IBM* System\370 floating-point data conversion in effect'VAXD'If the file is connected with little endian integer and VAX processor F_floating, D_floating, and H_floating in effect'VAXG'If the file is connected with little endian integer and VAX processor F_floating, G_floating, and H_floating in effect'NATIVE'If the file is connected with no data conversion in effect'UNKNOWN'If the file or unit is not connected for unformatted data transfer