Why is a modification of the GTS JESD204C IP Analog Parameter Settings not reflected in the generated Design Example?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® Prime Pro Edition Software version 24.2, the GTS JESD204C IP Analog Parameter Setting values in the generated Design Example remain at their default settings instead of reflecting any modifications made in the GTS JESD204C IP GUI. 

Resolution

To work around this problem, make the following changes :

  1.  In the generated Design Example project,  open the .IP file at the Project Navigator in the “IP Components” tab: 

    For TX: ../rtl/tx/ip/j204c_gts_tx_ip/j204c_gts_tx_ip_intel_jesd204c_gts.ip 
    For RX: ../rtl/rx/ip/j204c_gts_rx_ip/j204c_gts_rx_ip_intel_jesd204c_gts.ip 
    For Duplex: ../rtl/du/ip/j204c_gts_rx_tx_ip/j204c_gts_rx_tx_ip_intel_jesd204c_gts.ip 
  2.  Update the desired Analog Parameter values in the IP Parameter Editor GUI.
  3. Save the parameter settings. 
  4. Generate HDL to overwrite the .IP file, 
  5.  Close the GUI after generating the HDL. The new values will be updated. 

This problem has been fixed in version 24.3 of the Quartus® Prime Pro Edition Software.

1