This error message will be seen during compilation when using the Primitive DSP Native Fixed Point DSP Agilex™ FPGA IP and the "Enable disable_chainout" option is enabled.
This problem only affects the Agilex™ 5 and Agilex™ 7 devices.
To work around this problem, disconnect the disable_chainout port by setting parameter “Enable disable_chainout” to “No” in Native Fixed Point DSP Intel Agilex™ FPGA IP.
Recompile on your design in the Quartus® Prime Pro Edition Software version 24.3 or later. Or, download and install patch for your Quartus® Prime Pro Edition Software version and recompile your design.
Download and install Patch 0.00dsp for 23.1 from the appropriate link below:
- Download the version 23.1 patch 0.00dsp for Windows (.exe)
- Download the version 23.1 patch 0.00dsp for Linux (.run)
- Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 23.1 (.txt)
Download and install Patch 0.00dsp for 23.2 from the appropriate link below:
- Download the version 23.2 patch 0.00dsp for Windows (.exe)
- Download the version 23.2 patch 0.00dsp for Linux (.run)
- Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 23.2 (.txt)
Download and install Patch 0.00dsp for 23.3 from the appropriate link below:
- Download the version 23.3 patch 0.00dsp for Windows (.exe)
- Download the version 23.3 patch 0.00dsp for Linux (.run)
- Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 23.3 (.txt)
Download and install Patch 0.00dsp for 23.4 from the appropriate link below:
- Download the version 23.4 patch 0.00dsp for Windows (.exe)
- Download the version 23.4 patch 0.00dsp for Linux (.run)
- Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 23.4 (.txt)
Download and install Patch 0.00dsp for 24.1 from the appropriate link below:
- Download the version 24.1 patch 0.00dsp for Windows (.exe)
- Download the version 24.1 patch 0.00dsp for Linux (.run)
- Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 24.1 (.txt)
Download and install Patch 0.00dsp for 24.2 from the appropriate link below:
- Download the version 24.2 patch 0.00dsp for Windows (.exe)
- Download the version 24.2 patch 0.00dsp for Linux (.run)
- Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 24.2 (.txt)
For Agilex™ 7 and Agilex™ 5 design developed in Quartus® Prime Pro Edition Software prior to version 24.3, you may run the risk assessment script to check if your design is impacted.
Steps to run the script:
- Run EDA Netlist Writer with the successfully pre-compiled design.
- Insert the risk assessment script in the Quartus project folder
- Navigate to the Quartus project folder:
cd <quartus project path>
- Run the command:
tclsh screening.tcl ./simulation/questa/<project_name>.vo
- Follow the message prompted for next step.
For deployed designs with dynamic chainout enabled in the field, contact Altera by filing IPS case (stating bug ID 15017127180) for further queries.