Article ID: 000098305 Content Type: Troubleshooting Last Reviewed: 11/15/2024

Why do I have large periphery to core timing violations in my Agilex™ 5 design?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® Prime Pro Edition Software version 23.4, you might see large timing violations on paths from a register in an IO Cell to a register in the core. The problem occurs because the tool underestimates the delay between the periphery and the core.

    This problem only occurs in designs targeting Agilex™ 5 devices. 

     

     

    Resolution

    To work around this problem, use a Logic Lock Region to constrain the core register(s) close to the IO Cell. Alternative solutions are using a timing overconstraint or increasing the fitter effort.

    This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.