Due to a problem in Quartus® Prime Pro Edition Software version 23.2 and earlier, the SEU error queue will report a single-bit correctable error after a double-bit (non-adjacent) uncorrectable error has occurred. This problem may occur when the internal scrubbing feature is enabled in the Agilex™ 7 devices.
SEU detection and internal scrubbing will stop working after reporting this single-bit correctable error. No SEU error will be reported or corrected, the SEU error message queue will be empty, and the SEU_ERROR pin will be de-asserted.
This problem is fixed beginning with the Quartus® Prime Pro Edition Software version 23.3.