Article ID: 000094999 Content Type: Error Messages Last Reviewed: 05/19/2023

Why do EMIF Efficiency Monitor counters “No readdatavalid Count” & “Master Write Idle Count” continue to incorrectly increment in Intel® Quartus® Prime Pro Edition Software version 21.1 for Intel Agilex® 7 DDR4 IP EMIF Traffic Generator 1.0 completed?

Environment

    Intel® Quartus® Prime Design Software
    External Memory Interfaces Debug Component Intel® FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.1, you may encounter the EMIF Efficiency Monitor counters “No readdatavalid Count” and “Master Write Idle Count” continue to incorrectly increment after the Intel Agilex® 7 DDR4 IP EMIF Traffic Generator 1.0 (TG1) has completed sending traffic and subsequently resetting the Efficiency Monitor status registers by clicking on the Clear Status Registers button.

 

 

Resolution

This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 21.1.