Due to a problem in Intel® Quartus® Prime Pro Edition Software version 21.4 and earlier, you may see this error when using the Fault Injection Debugger tool and injecting an error to only the 'Not critical' area in Intel® Stratix® 10 device and Intel Agilex® device.
To fix this problem, download and install the latest device firmware patch according to your Intel® Quartus® Prime Pro Edition Software version.
- Intel® Quartus® Prime Pro Edition Software v21.1 - Patch 0.65fw or newer
- Intel® Quartus® Prime Pro Edition Software v21.2 - Patch 0.50fw or newer
- Intel® Quartus® Prime Pro Edition Software v21.3 - Patch 0.49fw or newer
- Intel® Quartus® Prime Pro Edition Software v21.4 - Patch 0.75fw or newer
You can find the latest device firmware patch for each Intel® Quartus® Prime Pro Edition Software version from the following Knowledge Data Base article.
What is the latest device firmware for Intel Agilex® and Intel® Stratix®10 devices?
This problem has been fixed since Intel® Quartus® Prime Pro Edition Software version 22.1.