Article ID: 000093233 Content Type: Troubleshooting Last Reviewed: 06/01/2023

What is the latest device firmware available for the Intel® Quartus® Prime Pro Edition Software version 22.3?

Environment

    Intel® Quartus® Prime Pro Edition
    Intel® Quartus® Prime Pro Edition Programmer and Tools
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

The latest device firmware for the Intel® Quartus® Prime Pro Edition Software version 22.3 can be downloaded from the following links.

Fixes for the following problems are included in the latest release (The newest release contains all prior fixes and supersedes earlier device firmware releases).

Change Log

FW version 0.27fw

- This patch fixes the SDM firmware bug that when the Sub-System Manager (SSM) RAM repair information is applied incorrectly, this RAM is inaccessible to users. The impacted Intel Agilex® OPNs are: AGF019, AGF023, AGI019, AGI023.

 

Please also see the following:

 - Updating the SDM Firmware in the Intel Agilex® Configuration User Guide

 - Updating the SDM Firmware in the Intel® Stratix® 10 Configuration User Guide

 

 

 

Resolution

Download the latest Device Firmware from the following links.

Note:  

  • Patches must be applied to the Intel® Quartus® Prime Pro Software and the Intel® Quartus® Prime Pro Edition Programmer and Tools.

  • Re-compilation is not required.

  • All Programming files should be re-created.

    •   Re-run programming file generation or conversion using the Intel® Quartus® Programming File Generator.  

Related Products

This article applies to 2 products

Intel® Stratix®
Intel Agilex® 7 FPGAs and SoC FPGAs