Article ID: 000092398 Content Type: Error Messages Last Reviewed: 10/06/2022

Error (13264): Can't resolve multiple constant drivers for net <*>

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 20.4, you might see this error when compiling during synthesis stage. This occurs when an array of structs is being assigned in a for-loop wrapped by an if/else block then wrapped by a generate block.

 

Resolution

A patch is available to fix this problem for the Intel® Quartus® Prime Pro Edition Software version 20.4. Download and install the patch from the following links:

This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 22.3.

Related Products

This article applies to 1 products

Intel® Programmable Devices