Description
Due to a problem with the firmware in the Intel® Agilex™ F-tile devices with the ordering part number (OPN) ending VR0, VR1 or VR2, the results of “eye width time” and “eye width UI” will return a 0 value when trying to run Eye Viewer to measure eye width in internal serial loopback mode.
Resolution
There is no workaround for this problem for devices with OPN ending VR0, VR1 or VR2.
This problem is fixed in newer Intel Agilex F-Tile devices with OPN ending VR3 or AA.