Article ID: 000089646 Content Type: Error Messages Last Reviewed: 01/09/2023

Critical Warning(12677): No exact pin location assignment(s)

Environment

    Intel® Quartus® Prime Pro Edition
    High Bandwidth Memory (HBM2) Interface Intel® FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

You may see this Critical Warning message in Intel® Quartus® Prime Pro Edition Software version 22.1 and earlier when compiling an Intel® Stratix® 10 design containing the High Bandwidth Memory (HBM2) Interface Intel® FPGA IP.
The warning will be associated with missing location assignments for m2u_bridge conduit signals.

 

 

Resolution

This message can be safely ignored for the m2u_bridge conduit signals since they are not connected to physical pins.

This message will be automatically suppressed starting from Intel Quartus Prime Pro Edition Software version 22.2.

Related Products

This article applies to 2 products

Intel® Stratix® 10 DX FPGA
Intel® Stratix® 10 MX FPGA

1