Article ID: 000089044 Content Type: Troubleshooting Last Reviewed: 03/01/2023

Why does Configuration via Protocol (CvP) fail after loading the periphery image into all Intel Agilex® devices successfully with a package code of R31C / R31B?

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a CvP upstream driver issue, CvP may intermittently fail after successfully loading the periphery image into all Intel Agilex® devices with package code R31C / R31B.

 

 

Resolution

To work around this problem, power cycle and re-initiate the CvP update after loading the periphery image successfully .

 

This issue is scheduled to be fixed in a future version of the CvP upstream driver.

 