Article ID: 000087345 Content Type: Error Messages Last Reviewed: 12/21/2022

Warning: <clk>/asmi_parallel2.clk: asmi_parallel2.clk requires 50000000Hz, but source has frequency of 100000000Hz

Environment

    Intel® Quartus® Prime Pro Edition
    ASMI Parallel II Intel® FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

This warning message will appear when the input clock for the ASMI Parallel II IP is not set to 'exactly' 50MHz. The maximum input clock frequency for the ASMI Parallel II IP is 50MHz.

Thus, the warning message will be cleared when the input clock is set to 50MHz. If you set the input clock below 50MHz, you can ignore the warning message.

Resolution

This problem is fixed in Intel® Quartus® Prime Software version 17.1.

Related Products

This article applies to 1 products

Intel® Arria® 10 FPGAs and SoC FPGAs

1