Article ID: 000086273 Content Type: Error Messages Last Reviewed: 01/11/2017

Critical Warning (18964): Dedicated HPS IO Voltage mismatch. The VCCIO_HPS is set as 1.8V but the HPS dedicated pin is set to an IO standard of 3.0V

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® Prime software version 16.1, Critical Warnings for dedicated HPS IO voltage mismatch may be erroneously generated for Arria® 10 HPS shared IO pins.

  • The legality check in the Quartus Prime software version 16.1 erroneously compares the VCCIO_HPS setting to the pins in the HPS shared IO48.
  • The VCCIO_HPS setting must the IO voltage in HPS dedicated IO. 

 

Resolution

This critical warning can be ignored in the 16.1 Quartus Prime software if:

  • VCCIO_HPS matches the voltage on HPS dedicated pins
  • The VCCIO on the relevant shared IO bank matches the IO standard on the HPS Shared IO Pin

This problem is scheduled to be fixed in a future release of the Quartus Prime software.

Related Products

This article applies to 1 products

Intel® Arria® 10 SX SoC FPGA