Article ID: 000084987 Content Type: Troubleshooting Last Reviewed: 09/11/2012

Is there an issue with the transceiver power estimation accuracy for Arria V devices when using the PowerPlay Power Analyzer in the Quartus II software version 11.1sp2?

Description The PowerPlay Power Analyzer in the Quartus® II software version 11.1sp2 and earlier versions may overpredict transceiver power in Arria® V devices.
Resolution

Use the Early Power Estimator (EPE) version 11.1sp2 to estimate the transceiver power in Arria V devices.

A future version of the PowerPlay Power Analyzer in the Quartus II software will have more accurate transceiver power estimation.