Article ID: 000081213 Content Type: Troubleshooting Last Reviewed: 10/21/2013

Why is the path to the ModelSim Altera Edition software set up incorrectly ?

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® II software version 13.0, after installation, the default path to the ModelSim-Altera software is incorrectly set to:

<install_directory>\win32aloem (for example, C:\altera\13.0.0.156\win32aloem)

Resolution

To correct this issue, open the Options dialog box by selecting Options on the Tools menu. Select the EDA Tool Options category, and change the path to the following:

<install_directory>\modelsim_ase\win32aloem (for example, C:\altera\13.0.0.156\modelsim_ase\win32aloem)

This problem is fixed beginning with the Quartus II software version 13.0 SP1.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1