Article ID: 000081063 Content Type: Troubleshooting Last Reviewed: 11/21/2011

Scaler II Generates Incorrect Output When It Receives Elongated Control Packet

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

The Scaler II MegaCore function with the Enable run-time control of input/output frame size option turned on may generate incorrect output when it receives an elongated control packet.

This issue affects your system if you instantiate the Scaler II Megacore function directly after you instantiate the Color Plane Sequencer or Chroma Resampler Megacore function.

The affected configuration may generate incorrect output or crash.

Resolution

None. Avoid using the Scaler II MegaCore function with the Enable run-time control of input/output frame size option turned on directly after the Color Plane Sequencer or Chroma Resampler Megacore function.

This issue is fixed in version 11.0 of the Video and Image Processing Suite.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1