Article ID: 000080359 Content Type: Troubleshooting Last Reviewed: 07/23/2020

Why are the Block Memory Bits in the Fitter Resource Utilization by Entity report incorrect?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition software version 20.1, you may see the incorrect data in the Block Memory Bits column of the Fitter Resource Utilization by Entity report. This problem occurs when targeting an Intel® Agilex™ device.

    Resolution

    To work around this problem, get the correct value for Block Memory bits from the Implementation Bits column of Fitter RAM Summary report. 

    This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime Pro Edition software. 