Article ID: 000079633 Content Type: Troubleshooting Last Reviewed: 01/31/2013

Why do I see combinationial loop warnings related to the Clocked Video Input megafunction?

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Clocked Video Input megafunction in the Quartus® II software version 10.1 SP1 and earlier, you may see the following warning when performing static timing analysis in the TimeQuest Timing Analyzer:

Warning: Found combinational loop of 6 nodes
    Warning: Node "<user hierarchy>|overflow_nxt~3|combout"
    Warning: Node "<user hierarchy>|avalon_st_output.packet_post_swap~0|datab"
    Warning: Node "<user hierarchy>|avalon_st_output.packet_post_swap~0|combout"
    Warning: Node "<user hierarchy>|overflow_nxt~4|datab"
    Warning: Node "<user hierarchy>|overflow_nxt~4|combout"
    Warning: Node "<user hierarchy>|overflow_nxt~3|dataa"
   
This issue may also be flagged as a Critical Design Assistant Warning such as:

Critical Warning: (Critical) Rule A101: Design should not contain combinational loops. Found 1 combinational loop(s) related to this rule.

This problem is scheduled to be resolved in a future release of the Quartus II software.

   

Resolution

Although this issue is not expected to cause any functional issues, it is recommended to upgrade to a version of the Quartus II software later than 10.1 SP1 when possible.

Related Products

This article applies to 1 products

Intel® Programmable Devices