Critical Issue

Description

This problem affects QDR II products.

QDR II/II interfaces targeting Arria V devices do not fully support the RTL-based sequencer. If you select the RTL-based sequencer, the resulting IP generates and simulates properly, but calibration in hardware is unreliable.

Resolution

The workaround for this issue is to use the Nios II-based sequencer.

This issue will be fixed in a future version.