Article ID: 000078361 Content Type: Error Messages Last Reviewed: 03/28/2016

Internal Error: Sub-system:ASMCC, File:/quartus/comp/asmcc/asmcc_bitfield.cpp,Line:989Assembler bitfield error: Found conflicting assignments for CRAM address:address=142

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® II software version 13.0 and later, you may see this internal error during the Assembler when compiling designs targeting Stratix® V, Arria® V, or Cyclone® V devices. This error occurs if two HSSI IP are placed in channel 0 and channel 1 of the same HSSI triplet, while their PPM are configured differently.

Resolution

To work around this problem in the Quartus II software version 13.0, download and install patch 0.dp2 from the related solution below.

This problem is fixed beginning with the Quartus II software version 13.0 SP1.

This issue is schedule to be fixed in a future release of the Quartus II software.

Related Products

This article applies to 12 products

Cyclone® V SX SoC FPGA
Cyclone® V GT FPGA
Stratix® V GX FPGA
Arria® V SX SoC FPGA
Stratix® V GT FPGA
Cyclone® V GX FPGA
Stratix® V GS FPGA
Arria® V GZ FPGA
Cyclone® V ST SoC FPGA
Arria® V ST SoC FPGA
Arria® V GX FPGA
Arria® V GT FPGA

1