Article ID: 000078335 Content Type: Troubleshooting Last Reviewed: 07/01/2013

Why does my partial reconfiguration design give invalid recommendations?

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® II software version 13.0, if you are using partial reconfiguration, you may see the following warning in the Design Partitions Window

Region <region name> contained logic from multiple partitions (<region name>, <region name>). Ensure that each region contains logic from one partition.

Additionally, you may see this warning in the Incremental Compilation Advisor Team-Based Recommendations

Do Not Place Logic From Multiple Partitions in One LogicLock Region
Resolution

This recommendation is incorrect for for partial reconfiguration designs and should be ignored. If you are not using partial reconfiguration, your design should be changed to avoid this warning.

This problem is scheduled to be fixed in a future release of the Quartus® II software.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1