Article ID: 000077288 Content Type: Troubleshooting Last Reviewed: 08/13/2012

Why does transceiver dynamic reconfiguration fail when the "Enable continuous write of all the words needed for reconfiguration" option is enabled in the altgx_reconfig MegaWizard on Stratix IV GX/T and Arria II GX/GZ devices?

Environment

  • Arria® II GZ FPGA
  • Arria® II GX FPGA
  • Stratix® IV GT FPGA
  • Stratix® IV GX FPGA
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Transceiver dynamic reconfiguration may fail when the "Enable continuous write of all the words needed for reconfiguration" option is enabled in the altgx_reconfig MegaWizard™ on Stratix® IV GX/GT and Arria® II GX/GZ devices due to a problem with the altgx_reconfig MegaWizard.

Asserting the write_all signal for one reconfig_clk clock cycle may cause the dynamic reconfiguration process to fail with Quartus® II Software Versions 10.0-SP1 and earlier.

To work around this issue, assert the write_all signal for four reconfig_clk cycles, or upgrade to Quartus II Software Version 10.1 or later.

Disclaimer