Article ID: 000077096 Content Type: Error Messages Last Reviewed: 10/06/2014

Error: PLL Parameters for the device family Cyclone III could not be read

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

You may see this error in the Quartus® II software version 14.0 when you open a design from a previous version of the Quartus II software. This errors occurs when the design contains an ALTPLL IP core and targets a Cyclone® III device. The Cyclone III device family is not supported in the Quartus II software version 14.0.

In addition to the error message, you cannot modify or migrate this design in the Quartus II software v14.0.

Resolution

To avoid this error, perform one of the following actions

  • Do not upgrade the Quartus II software to v14.0
  • In the Quartus II software v13.1, change the device family to one supported in version 14.0

Related Products

This article applies to 2 products

Cyclone® III LS FPGA
Cyclone® III FPGAs

1