Article ID: 000076917 Content Type: Troubleshooting Last Reviewed: 06/15/2015

Compiler error: "If ECC is enabled, Scrubbing should also be enabled."

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

The preloader generator disables SDRAM ECC bit initialization by default. If the SDRAM ECC is enabled, the following compiler error appears:

If ECC is enabled, Scrubbing should also be enabled.
Resolution

If the SDRAM ECC is enabled, enable SDRAM ECC bit initialization in the preloader generator.

Related Products

This article applies to 3 products

Arria® V FPGAs and SoC FPGAs
Intel® Arria® 10 FPGAs and SoC FPGAs
Cyclone® V FPGAs and SoC FPGAs

1