Description
Due to a problem in the Triple Speed Ethernet (TSE) MegaCore® Function, the CNT_RESET register does not clear the following 64-bit statistic counters.
- aOctetsTransmittedOK
- aOctetsReceivedOK
- etherStatsOctets
Resolution
Set SW_RESET to 1 to clear the octet counters.
This problem will be fixed in a future version of the Quartus® II software.