Article ID: 000076755 Content Type: Troubleshooting Last Reviewed: 12/06/2024

An error occurred while linking the project to the device

Environment

    Intel® Quartus® Prime Pro Edition
    External Memory Interfaces Intel® Arria® 10 FPGA IP
    External Memory Interfaces Intel® Stratix® 10 FPGA IP
    External Memory Interfaces Intel® Cyclone® 10 FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

Due to a problem in the Quartus® Prime Pro Edition Software version 19.3, you may see a design link error in the EMIF Toolkit with the following message:

"An error occured while linking the project to the device"

 

Resolution

Once a programming .sof file is linked through the "Link Project to Device" step in the EMIF Toolkit, and then unlinked through the "Unlink Project from Device" step, the same programming .sof file can't be re-linked through the "Link Project to Device" step again. If this is required, you will need to close the EMIF Toolkit and then re-open it.

Related Products

This article applies to 3 products

Intel® Arria® 10 FPGAs and SoC FPGAs
Intel® Stratix® 10 FPGAs and SoC FPGAs
Intel® Cyclone® 10 FPGAs