Article ID: 000076718 Content Type: Troubleshooting Last Reviewed: 06/17/2016

Why do unused transceiver TX channels in my Arria 10 device degrade over time?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Unused transceiver TX channels in your Arria® 10 device may degrade over time when using the Quartus® Prime software version 16.0 and earlier.

The Quartus Prime software generates a warning message if your design contains unused transceiver channels. The warning message states that performance of unused channels may degrade over time if not properly preserved with the following Quartus Settings File (QSF) assignments. 

Global Assignment

set_global_assignment -name PRESERVE_UNUSED_XCVR_CHANNEL ON

Pin Specific Assignment

set_instance_assignment -name PRESERVE_UNUSED_XCVR_CHANNEL ON -to pin_name

In the Quartus Prime software version 16.0 and earlier, the QSF assignment only preserved the unused receiver channel and did not properly preserve the unused transmitter channel.

Resolution

To preserve the performance of unused transmitter and receiver channels in Arria 10 devices you should recompile your design in Quartus Prime software version 16.0.1 or later.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1