Article ID: 000076488 Content Type: Troubleshooting Last Reviewed: 10/08/2020

When using Intel® Stratix® 10 how do I recover from an error state after sending a corrupted partial reconfiguration bitstream?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Partial Reconfiguration Controller Intel® Arria® 10 Cyclone® 10 FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    When the Intel® Stratix® 10 Partial Reconfiguration Controller Intel® FPGA IP detects a corrupted partial bitstream, it sets status[2..0] = 3'b100 = PR_ERROR is triggered. The avst_sink_ready signal is de-asserted and the Partial Reconfiguration Controller Intel® FPGA IP will not accept any further partial reconfiguration bitstream until the IP is reset using the reset port.

    Before resetting the Partial Reconfiguration Controller Intel® FPGA IP it is necessary to ensure that the remaining partial bitstream is flushed from the Avalon® streaming pipeline, and only then assert the reset to the Partial Reconfiguration Controller Intel® FPGA IP.
     

    Resolution

    To work around this problem implement RTL to monitor the status[2..0] port and generate a dummy avst_sink_ready signal to the Intel® Stratix® 10 Partial Reconfiguration Controller Intel® FPGA IP Master when PR_ERROR is indicated and ensure avst_sink_valid has finished toggling. This will ensure the remaining partial reconfiguration bitstream is flushed from the Avalon® streaming pipeline, then apply the reset to the Intel® Stratix® 10 Partial Reconfiguration Controller Intel® FPGA IP.

    Once completed it will be possible to start sending a new good partial reconfiguration bitstream to the Partial Reconfiguration Controller Intel® FPGA IP.