Article ID: 000074966 Content Type: Troubleshooting Last Reviewed: 05/20/2024

RSU : Sub-partition table magic number not match 0x62294895

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

While running Hard Processor System (HPS) based Remote System Update on Agilex™ 7 SoC FPGAs, you may see the above message as a result of running the ‘rsu list’ command from the HPS. This is because the U-Boot detects a mismatched magic number due to an incompatible version of DCMF found on the attached flash device.

Resolution

To work around this problem, update the DCMF to version 20.3 to allow RSU to function correctly if using RSU features with versions of Quartus® Prime Pro Edition Software earlier than version 20.3 