Article ID: 000074622 Content Type: Troubleshooting Last Reviewed: 05/31/2017

Why is an unexpected functional failure observed on Arria 10 devices when performing fault injection with the Fault Injection Debugger IP?

Environment

    Intel® Quartus® Prime Pro Edition
    Advanced SEU Detection Intel® FPGA IP
    Fault Injection Intel® FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to an issue in Quartus® Prime software versions earlier than 17.0, the Fault Injection Debugger IP may cause CRAM corruption during fault injection in Arria® 10 devices, which may lead to one of the following failures :

- Fault Injection IP not found.

- Lost SignalTap instance.

- Failure to read the Error Message Register (EMR) or read invalid EMR content.

- Internal Scrubbing cannot recover the functional failure in user logic.

 

Resolution

This issue is resolved in Quartus® Prime software version 17.0.

Related Products

This article applies to 1 products

Intel® Arria® 10 FPGAs and SoC FPGAs

1