Article ID: 000074037 Content Type: Troubleshooting Last Reviewed: 08/15/2023

Why does IP Parameter Editor fail to create a new Fixed Point Functions Intel® FPGA IP?

Environment

    Intel® Quartus® Prime Pro Edition
    Fixed Point Functions Intel® FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 19.1 and 19.2 for Windows*, you may see that the IP Parameter Editor will close abruptly when creating a new instance of the Fixed Point Functions Intel® FPGA IP.

 The IP Parameter Editor window will not show any error messages.

Resolution

To work around this problem for the Intel® Quartus® Prime Pro Edition Software version 19.1, please migrate your design to the Intel® Quartus® Prime Pro Edition Software version 19.2 and install Patch 0.12, available for download in this solution.

A patch is available to fix this problem for the Intel® Quartus® Prime Pro Edition Software version 19.2. Download and install Patch 0.12 from the link below.

Please read carefully the ReadMe file for patch 0.12, this patch requires that DSPBA_DEVICE_XML_OVERRIDE environmental variable is set in your system and that QUARTUS_ROOTDIR environmental variable is pointing to your Intel® Quartus® Prime Pro Edition software version 19.2 installation folder.

This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 20.1.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1