The following table lists storage system events detected by the monitoring service (IAStorDataMgrSvc):
Event Type | Event Level | String | Event Displayed | ||
NAI1 (Notification Area Icon) | Event Log | Email Notify2 | |||
Disk Triggered Events | |||||
Failed | Error | Disk on port {n}: Failed. Open the application for details. | Yes | Yes | Yes |
S.M.A.R.T. | Warning | Disk on port {n}: At risk. Open the application for details. | Yes | Yes | Yes |
Unlocked | Info | Disk on port {n}: Unlocked. | Yes | Yes | Yes |
Added | Info | Disk on port {n}: Detected. | Yes | Yes | Yes |
Removed | Info | Disk on port {n}: Removed. | Yes | Yes | Yes |
Volume Triggered Events | |||||
Failed | Error | Volume {0}: Failed. Open the application for details. | Yes | Yes | Yes |
Degraded | Warning | Volume {0}: Degraded. Open the application for details. | Yes | Yes | Yes |
Detected | Info | A new volume was found. | Yes | Yes | Yes |
RebuildComplete | Info | Volume {0}: Rebuilding complete. | Yes | Yes | Yes |
VerifyStop | Info | Volume {0}: Verification complete. | Yes | Yes | Yes |
VerifyAndRepairStop | Info | Volume {0}: Verification and repair complete. | Yes | Yes | Yes |
MigrationComplete | Info | Volume {0}: Data migration complete. | Yes | Yes | Yes |
InitializeComplete | Info | Volume {0}: Initialization complete. | Yes | Yes | Yes |
Unlocked | Info | Volume {0}: Unlocked. | Yes | Yes | Yes |
NotPresent | Info | Volume {0}: No longer present on system. | Yes | Yes | Yes |
RebuildStarted | Info | Volume {0}: Rebuilding in progress. | Yes | No | No |
VerifyStarted | Info | Volume {0}: Verification in progress. | Yes | No | No |
VerifyAndRepairStarted | Info | Volume {0}: Verification and repair in progress. | Yes | No | No |
MigrationStarted | Info | Volume {0}: Data migration in progress. | Yes | No | No |
InitializeStarted | Info | Volume {0}: Initialization in progress. | Yes | No | No |
General Events | |||||
ServerStartFailed | Error | Server failed to start. Additional information: | No | Yes | Yes |
EventManagerStarted | Info | Started the event manager. | No | Yes | Yes |
1 NAI true only if the user selected to receive notification under Preferences in the Intel® VROC Graphical User Interface (GUI) application.
2 Refer to the section Email Alerting and Notification in Intel® Virtual RAID on CPU (Intel® VROC) Miscellaneous Features and Functionality in Windows* for email feature support.
The following table outlines the events that will be logged and their corresponding event:
Event ID | Message Definition | Severity/Level | Message |
4097 | START_READ_PATROL_LOG | Info | Started Patrol on RAID Volume %2. |
4098 | STOP_READ_PATROL_LOG | Info | Stopped Patrol on RAID Volume %2. |
4099 | ERROR_READ_PATROL_LOG | Warning | Read Patrol detected error on RAID Volume %2 at LBA %3 on member disk %4 at PBA %5. |
4100 | RECOVERY_READ_PATROL_LOG | Info | Read Patrol detected and recovered bad blocks on the RAID volume %2. |
4101 | NO_RECOVERY_READ_PATROL_LOG | Error | Read Patrol detected and failed to recover bad blocks on the RAID volume %2. |
4102 | BBM_INFO_LOG | Info | Bad Block Management currently found %2 bad blocks and a max capacity for %3 bad blocks on array %4. |
4103 | DISK_ERROR_SMART_LOG | Error | Error log: Smart event occurred on disk %2. |
4104 | DISK_ADDED_ON_RUNTIME_LOG | Info | Disk %2 has been hot plugged. |
4105 | DISK_REMOVED_ON_RUNTIME_LOG | Info | Disk %2 has been hot unplugged. |
4106 | DISK_MARK_AS_SPARE_LOG | Info | Disk %2 has been marked as spare. |
4107 | DISK_UNMARK_AS_SPARE_LOG | Info | Disk %2 is no longer a spare. |
4108 | DISK_MARK_AS_OFFLINE_LOG | Info | Disk %2 is offline array member. |
4110 | DISK_IN_FAILED_STATE_LOG | Error | Disk %2 is in failed state. |
4111 | DISK_IN_NORMAL_STATE_LOG | Info | Disk %2 is in normal state. |
4112 | DISK_MANAGE_UNPLUG_LOG | Info | Disk %2 has been managed unplugged. |
4113 | CONTROLLER_READ_PATROL_ENABLE_LOG | Info | Read Patrol has been enabled. |
4114 | CONTROLLER_READ_PATROL_DISABLE_LOG | Info | Read Patrol has been disabled. |
4115 | CONTROLLER_ROHI_ENABLE_LOG | Info | Rebuild on Hot Insert has been enabled. |
4116 | CONTROLLER_ROHI_DISABLE_LOG | Info | Rebuild on Hot Insert has been disabled. |
4117 | VOLUME_CREATE_LOG | Info | RAID volume %2 has been created. |
4118 | VOLUME_DELETE_LOG | Info | RAID volume %2 has been deleted. |
4119 | VOLUME_RENAME_LOG | Info | RAID volume %2 has changed name to %3. |
4120 | VOLUME_MIGRATION_START_LOG | Info | Migration of RAID volume %2 has started. |
4121 | VOLUME_MIGRATION_FINISH_LOG | Info | Migration of RAID volume %2 has successfully finished. |
4122 | VOLUME_MIGRATION_FAILED_LOG | Error | Migration of RAID volume %2 has failed. |
4123 | VOLUME_MIGRATION_SUSPEND_LOG | Info | Migration of RAID volume %2 is suspended. |
4124 | VOLUME_MIGRATION_RESUME_LOG | Info | Migration of RAID volume %2 is resumed. |
4125 | VOLUME_INITIALIZE_START_LOG | Info | Initialization of RAID volume %2 has started. |
4126 | VOLUME_INITIALIZE_FINISH_LOG | Info | Initialization of RAID volume %2 has successfully finished. |
4127 | VOLUME_INITIALIZE_FAILED_LOG | Error | Initialization of RAID volume %2 has failed. |
4128 | VOLUME_INITIALIZE_SUSPEND_LOG | Info | Initialization of RAID volume %2 is suspended. |
4129 | VOLUME_INITIALIZE_RESUME_LOG | Info | Initialization of RAID volume %2 is resumed. |
4130 | VOLUME_VERIFY_START_LOG | Info | Verify process on RAID volume %2 has started. |
4131 | VOLUME_VERIFY_FINISH_LOG | Info | Verify process on RAID volume %2 has successfully finished. |
4132 | VOLUME_VERIFY_FAILED_LOG | Error | Verify process on RAID volume %2 has failed. |
4133 | VOLUME_VERIFY_SUSPEND_LOG | Info | Verify process on RAID volume %2 is suspended. |
4134 | VOLUME_VERIFY_RESUME_LOG | Info | Verify process on RAID volume %2 is resumed. |
4135 | VOLUME_VERIFY_AND_FIX_START_LOG | Info | Verify and fix process on RAID volume %2 has started. |
4136 | VOLUME_VERIFY_AND_FIX_FINISH_LOG | Info | Verify and fix process on RAID volume %2 has successfully finished. |
4137 | VOLUME_VERIFY_AND_FIX_FAILED_LOG | Error | Verify and fix process on RAID volume %2 has failed. |
4138 | VOLUME_VERIFY_AND_FIX_SUSPEND_LOG | Info | Verify and fix process on RAID volume %2 is suspended. |
4139 | VOLUME_VERIFY_AND_FIX_RESUME_LOG | Info | Verify and fix process on RAID volume %2 is resumed. |
4140 | VOLUME_REBUILD_START_LOG | Info | Rebuild on RAID volume %2 has started. |
4141 | VOLUME_REBUILD_FINISH_LOG | Info | Rebuild on RAID volume %2 has successfully finished. |
4142 | VOLUME_REBUILD_FAILED_LOG | Error | Rebuild failed on RAID volume %2. |
4143 | VOLUME_REBUILD_SUSPEND_LOG | Info | Rebuild on RAID volume %2 is suspended. |
4144 | VOLUME_REBUILD_RESUME_LOG | Info | Rebuild on RAID volume %2 is resumed. |
4145 | VOLUME_WBC_ENABLE_LOG | Info | Write-back cache is enabled on RAID volume %2. |
4146 | VOLUME_WBC_DISABLE_LOG | Info | Write-back cache is disabled on RAID volume %2. |
4147 | VOLUME_STATE_DEGRADED_LOG | Warning | RAID volume %2 is degraded. |
4148 | VOLUME_STATE_FAILED_LOG | Error | RAID volume %2 is failed. |
4149 | VOLUME_STATE_NORMAL_LOG | Info | RAID volume %2 is normal. |
4150 | HIBERNATE_SUSPEND_LOG | Info | Platform is entering hibernation. |
4151 | SLEEP_SUSPEND_LOG | Info | Platform is entering standby. |
4152 | RESUMING_LOG | Info | Platform is resuming. |
4153 | POWER_UP_LOG | Info | Platform is powering up. |
4154 | VOLUME_REBUILD_FAILED_BBL_FULL_LOG | Error | Rebuild of RAID volume %2 failed, because bad block table is full. |
4155 | IO_FAILED_LOG | Warning | IO on %2 has failed. (Supported up to Intel® VROC 8.5. Replaced with 4162, 4163 and 4164 below starting with Intel® VROC 8.6) |
4156 | IO_TIMEOUT_LOG | Warning | IO on %2 has reached timeout. |
4157 | BAD_BLOCK_DETECTED | Warning | Bad block detected on drive %2 under LBA %3. |
4158 | BAD_BLOCK_FIXED | Info | Bad block successfully fixed on drive %2 under LBA %3. |
4159 | UNRECOVERABLE_BAD_BLOCK | Error | Bad block under drive's LBA %2 which is member of a RAID volume %3 could not be recovered. |
4160 | AHCI_PORT_INTERRUPT_STATUS | Warning | AHCI port %2 interrupt error status: PxIS = %3. |
4162 | ODD_EMPTY_DRIVE_IO_FAILED_LOG | Warning | I/O issued to empty Optical Disk Drive (media not present) model: <Model>, serial: <SerialNumber>, port: <PortNumber>. (Supported starting with Intel® VROC 8.6) |
4163 | SATA_DRIVE_IO_FAILED_LOG | Warning | I/O on drive model: <Model>, serial: <SerialNumber>, port: <PortNumber> has failed. (Supported starting with Intel® VROC 8.6) |
4164 | NVME_DRIVE_IO_FAILED_LOG | Warning | I/O on drive model:<Model>, serial: <SerialNumber> has failed. (Supported starting with Intel® VROC 8.6) |