How Do I Interconnect the Intel® RAID Adapter RS3P4TF160F and the Intel® Server System M50FCP1UR204 to Create a RAID 10?

Content Type: Connectivity   |   Article ID: 000095466   |   Last Reviewed: 03/19/2026

Environment

Operating System

OS Independent family
Intel® Server System M50FCP1UR204 Intel® RAID Adapter RS3P4TF160F 1U Hot-swap backplane spare CYPHSBP1204 SlimSAS SSD Cable x4 860mm & 1.0m (RAID to HSBP CYPCBLSLSLX8)

Description

What is the cable part number required to interconnect the Intel® RAID Adapter RS3P4TF160F with the 1U Hot-swap backplane spare CYPHSBP1204 within the Intel® Server System M50FCP1UR204 that has the Intel® Server Board M50FCP2SBSTD?

Resolution

The cable model required is: SlimSAS SSD Cable x4 860mm & 1.0m (RAID to HSBP CYPCBLSLSLX8)

example screenshot

Additional information

See the Hardware User Guide for Tri-mode Intel® RAID Adapters (RS3P4 Family)

  • Section "Connectivity and Drive Support" shows the SFF-8654 (SlimSAS 8i) connector.
  • The RAID controller connects to the backplane using an SFF-8654 8i to SFF-8654 8i cable. Recommended cable kit CYPCBLSLSLX8 (SlimSAS SSD Cable x4 860mm & 1.0m (RAID to HSBP CYPCBLSLSLX8)) (two cables, 1 x 860 mm, 1 x 1000 mm)."
Note Both cables must be connected, even if only one or two NVMe* drives are being installed for clocking purposes.