Skip To Main Content
Support Knowledge Base

After Power Recycle D50TNP Comes Back with Very Slow Performance

Content Type: Maintenance & Performance   |   Article ID: 000094639   |   Last Reviewed: 04/20/2023

Environment

D50TNP

Description

When D50TNP with an enclosure of 4 nodes, experiences 1 Node failure, and after power recycling all Nodes from the D50TNP system experience a very slow behavior.

Normal boot time usually takes 1 min but after the power recycle the node takes up to 7 mins.

Resolution

This is a known issue published on the Specification Update for Intel® Server D50TNP

For a fix, an IPMI command needs to be executed as follows:

  1. Run the IPMI command: ipmitool -b 0x06 -t 0x2c raw 0x2e 0xdf 0x57 0x01 0x00 0x02
  2. Restart the D50TNP system
  3. Check if the issue is fixed by monitoring the system performance.

If you still experiencing issues, please generate BMC log files and submit a  support ticket for analysis.

Related Products