Article ID: 000057790 Content Type: Troubleshooting Last Reviewed: 07/23/2021

How to Update the CPU Sensor Readings of the Integrated Baseboard Management Controller (Integrated BMC) without Installing the Whole System Update Package (SUP) on Intel® Server Board S2600STBR

Environment

osindependentfamily

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Summary

Steps to update the Sensor Data Record of the Integrated Baseboard Management Controller (Integrated BMC)

Description

Unable to see the CPU sensors in the Integrated Baseboard Management Controller (Integrated BMC) Embedded Web Server.

Resolution

Update the Field Replaceable Unit/Sensor Data Record (FRUSDR) only to obtain accurate Sensor Readings in the Integrated BMC Web Server:

  1. Press F2 to enter BIOS and select Internal EFI shell in the Boot Manager tab. A shell prompt appears on the screen.
  2. Run map –r to display all the drives available under the shell.
  3. Change to the current directory containing the FRUSDR package.
  4. Run UpdS2600STBFRUSDR.nsh.
Additional information

Related Products