Article ID: 000080489 Content Type: Troubleshooting Last Reviewed: 04/14/2024

Why does the EDA Simulation Library Compiler GUI fail to recognize the Cadence Xcelium* Parallel Simulator executable path?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® Prime Pro Edition Software version 20.4 and earlier, the EDA Simulation Library Compiler GUI cannot recognize the Cadence Xcelium* Parallel Simulator tool's executable path even if the xmsim bin path is provided.

     

    Resolution

    As a workaround, use the command line instead. 

    quartus_sh --simlib_comp -family <device family> -tool <EDA tools> -tool_path <path to simulation tool executable> -language <verilog/vhdl> -directory <output directory> -log <filename> -cmd_file <output_cmd file> -suppress_messages

    This problem has been fixed beginning with the Quartus® Prime Pro Edition Software version 21.1.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices