ID:169036 I/O pin <name> with setting <name> assigned to I/O bank <name> but bank does not contain OCT_RUP or OCT_RDN location
CAUSE: You assigned the specified
Termination
logic option setting to the specified I/O pin and assigned that I/O pin to the specified I/O bank. But the bank does not contain the OCT_RUP
or OCT_RDN
location that is required by the Termination logic option.
ACTION: Assign the I/O pin with the Termination logic option setting to a different I/O bank, or delete the logic option assignment on the I/O pin.