4.6.1. Launching and Setting Up the Fault Injection Debugger
4.6.2. Configuring Your Device using a Software Object File (.sof)
4.6.3. Constraining Regions for Fault Injection
4.6.4. Injecting Errors to Predefined Safe Locations
4.6.5. Blowing Fuse Bit to Enable Injecting All Error Types
4.6.6. Injecting Errors to Random Locations
4.6.7. Injecting Errors to Specific Locations
4.6.8. Injecting Double Adjacent Errors
4.6.9. Injecting SDM ECC Errors
4.6.10. Analyzing SEU or SDM ECC Errors Using Signal Tap
5.1.1. Advanced SEU Detection IP Parameter Settings
Parameters | Value | Default Value | Description |
---|---|---|---|
Use on-chip sensitivity processing |
|
On | Select to use external memory interface to access sensitivity data and perform SEU location look-up by the IP. |
Largest ASD region ID used | 1 to 32 | 1 | Specifies the largest ASD region ID used in the design. This option is available if you turn on Use on-chip sensitivity processing. The maximum number of region IDs classifications you can use in a design is 164. |
Sensitivity data start address | 0x0 | 0x0 | Specifies a constant offset to add to all addresses generated by the external memory interface. This option is available if you turn on Use on-chip sensitivity processing. |
Show raw SEU error message |
|
Off | Select to show raw SEU error message. This option is available if you turn on Use on-chip sensitivity processing. |
SEU error fifo depth |
|
4 | Specifies the number of SEU errors to store. |
Enable generic SDM error handling |
|
Off | Select to enable generic SDM error handling. |
Use with Fault Injection Debugger Tool |
|
Off | Turn on to use the IP with the Fault Injection Debugger tool. |
Export SEU_Error |
|
Off | Select to export SEU_ERROR as IP output signal, assert when SEU_ERROR detected. |
Related Information
4 Number of region ID in-use is limited by the region mask specified in the .smh.