v2.1.3 Issues corrected:
- Powerdown of groups only checked for one rail instead of all POKs low before sequencing next group.
- Retries and timeout values were not being passed to sequencer when PMBus was disabled.
v2.1.2 Removed "Altera Confidential" from footer and rounded off resource estimates in the User's Guide.
v2.1.1 Increased max number of ADC channels in VMonDecode from 9 to 17; corrected indexing of delays in PowerSequencer when the "Power Groups" option is used.