Article ID: 000099578 Content Type: Troubleshooting Last Reviewed: 08/21/2024

Why does External Memory Interface (EMIF) calibration fail on A5ED013BB23AE4/5/6SR0 devices when using Quartus® Prime Pro Edition Software version 24.2?

Environment

  • Intel® Quartus® Prime Design Software
  • External Memory Interfaces (EMIF) IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Quartus® Prime Pro Edition Software version 24.2, you might see EMIF calibration failure when targeting the following Agilex™ 5 devices.

    To enable the hardware support for External Memory Interfaces for the following OPNs in Quartus® Prime Pro Edition Software version 24.2, please install patch 0.09.

    • A5ED013BB23AE4SR0
    • A5ED013BB23AE5SR0
    • A5ED013BB23AE6SR0
    Resolution

    Download and install Patch 0.09 for the Quartus® Prime Pro Edition Software version 24.2.

    Then, generate the EMIF IP and compile the design after installing the patch Quartus® Prime Pro Edition Software v24.2 Patch 0.09.